TEXWIPE CO -- TX3507 OFFICE DUSTER 3 -- 6850-00F035949
===================== Product Identification =====================
Product ID:TX3507 OFFICE DUSTER 3
MSDS Date:09/01/1995
FSC:6850
NIIN:00F035949
=== Responsible Party ===
Company Name:TEXWIPE CO
Address:650 E CRESCENT AVE
Box:575
City:UPPER SADDLE RIVER
State:NJ
ZIP:07458-1827
Country:US
Info Phone Num:800-327-5577/201-327-9100
Emergency Phone Num:800-284-5577/201-327-9100
Preparer's Name:SCOTT PAHY
CAGE:21994
=== Contractor Identification ===
Company Name:TEXWIPE CO
Address:650 E CRESENT AVE
Box:308
City:UPPER SADDLE RIVER
State:NJ
ZIP:07458-1827
Country:US
Phone:201-327-5577
CAGE:21994
============= Composition/Information on Ingredients =============
Ingred Name:1,1,1,2-TETRAFLUOROETHANE (R134A)
CAS:811-97-2
Fraction by Wt: 100%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: VAPORS REDUCE OXYGEN
LEVELS IN AIR TO 12-14%. MAY CAUSE ASPHYXIATION, CARDIAC
SENSITIZATION, CARDIAC ARRYTHMIAS. SKIN: MAY CAUSE IRRITATION,
FROSTBITE. EYES: VAPORS CAN PRODUCE MILD IRRITA TION. LIQUID CAN
RESULT IN SEVERE IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:ASPHYXIATION, LOSS OF COORDINATION, INCREASED
PULSE RATE, DEEPER RESPIRATION, IRRITATION, DEFATTING, FROSTBITE,
Medical Cond Aggravated by Exposure:PRE-EXISTING DISEASES OF CNS,
CARDIOVASCULAR SYSTEM, ANEMIA, ASTHMA/DERMAL SENSITIVITY.
======================= First Aid Measures =======================
First Aid:EYES: IRRIGATE W/WATER FOR 15 MINS. SKIN: FLUSH W/WATER.
TREAT FOR FROSTBITE. INHALATION: REMOVE TO FRESH AIR.
RESTORE/SUPPORT BREATHING AS NEEDED. GIVE OXYGEN IF BREATHING IS
DIFFICULT. OBTAIN MEDICA L ATTENTION IN ALL CASES. NOTE TO
PHYSICIAN: BECAUSE OF A POSSIBLE DISTURBANCE OF CARDIAC RHYTHM,
CATECHOLAMINE DRUGS SUCH AS EPINEPHRINE, SHOULD BE USED W/SPECIAL
CAUTION IN EMERGENCY LIFE SUPPORT.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:NONE
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS MAY BE
REQUIRED IF CANS RUPTURE/CONTENTS RELEASED UNDER FIRE CONDITIONS.
Unusual Fire/Explosion Hazard:CONTAINERS MAY RUPTURE UNDER ELEVATED
TEMP CONDITIONS. IRRITATING & TOXIC GASES MAY BE PRODUCED.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA IN LOW PLACES WHERE HEAVY
VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES. LARGE: USE SELF-CONTAINED
BREATHING APPARATUS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SELF CONTAINED BREATHING APPARATUS IS REQUIRED
IF LARGE RELEASE OCCURS.
Ventilation:LOCAL EXHAUST WHEN LARGE AMOUNTS RELEASED. MECHANICAL
VENTILATION SHOULD BE USED IN LOW PLACES.
Protective Gloves:LINED NITRILE/NATURAL RUBBER
Eye Protection:CHEMICAL SPLASH GOGGLES
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:15.7F
Vapor Pres:84
Vapor Density:4.34
Spec Gravity:1.21
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUIFIED GAS W/SLIGHT ETHEREAL ODOR
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI/ALKALINE EARTH METALS, POWDERED ALUMINUM, ZINC
Stability Condition to Avoid:OPEN FLAMES, HIGH TEMPERATURES, GLOWING
METAL SURFACES
Hazardous Decomposition Products:HYDROCHLORIC & HYDROFLUORIC ACIDS,
POSSIBLY CARBONYL HALIDES
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.